Skip to content

Commit

Permalink
Ejecta modified to be more self-consistent with empirical data on eje…
Browse files Browse the repository at this point in the history
…cta thickness (calibrated for strengthless soft rock)
  • Loading branch information
daminton committed Dec 5, 2016
1 parent fcfa922 commit 7e8b6fc
Showing 1 changed file with 1 addition and 1 deletion.
2 changes: 1 addition & 1 deletion src/ejecta/ejecta_thickness.f90
Original file line number Diff line number Diff line change
Expand Up @@ -45,7 +45,7 @@ subroutine ejecta_thickness(user,crater,erad1,erad2,lrad1,lrad2,thick)
if (crater%imp < user%basinimp) then
! compute ejecta thickness
ce1sq = (2._DP / (CT * CT)) * mu**2 / (1._DP + 2 * mu + mu**2)
excav = abs(0.5_DP * ce1sq * PI * (erad2**3 - erad1**3))
excav = 7.43_DP * (crater%fcrat)**(-0.26_DP) * abs(0.5_DP * ce1sq * PI * (erad2**3 - erad1**3))
else
edDt = 1.150_DP ! Calibrated to Orientale using Fasset et al. 2011
excav = abs(0.5_DP * edDt * PI * (erad2**3 - erad1**3))
Expand Down

0 comments on commit 7e8b6fc

Please sign in to comment.